Full manual →

Quick start · one page

SiteEnergy — your first project

The system works from 8 760 hours of data, not monthly averages. In return it asks for one thing: run the steps in the right order, because several calculations read data that an earlier step wrote.

What you will need

Without these three, the first project stalls.

A consumption curve .xlsx, .xls or .csv, hourly or finer, ideally covering a full year. This is grid draw, not total consumption.
The exact site address Coordinates are needed for weather and solar data. The built-in geocoder or a click on the map provides them.
Prices Electricity price (fixed or stock), feed-in price, and gas or district-heating price if you have such a demand. You can also pick from the tariff catalogue.

The workflow — nine steps

Keeping the order prevents half of the common mistakes.

1
Create a location

Name, address, then coordinates. Without coordinates there is no weather or solar data.

2
Prices and tariff

On the location data sheet. The euro value is canonical, the forint is mirrored.

3
Consumption curve

Load it, then check the row count and the detected granularity.

4
Fetch the weather

On the location data sheet, with the measurement year. Building calculations require it.

5
Existing systems

Solar (“⚙ Fetch and calculate hourly data”) and battery.

6
Energy demands

Heat, hot water, buildings. Run “Calculate hourly data” on each one.

7
Energy flow (EFC)

Where it all comes together: self-consumption, feed-in, battery, cost, self-sufficiency.

8
Planned developments

Add what you want to examine, then optimize or evaluate them one by one.

9
Report

System report, and if your plan includes it: MEKH filing, ESG, ISO 50001.

What the numbers mean

T-curve Measured grid draw. Not total consumption — solar energy consumed on site never passed through the meter.
Self-sufficiency (%) 1 − (grid draw − feed-in) / total consumption. An annual net balance; 100% does not mean off-grid operation.
Confidence (%) How much of the result rests on measurement rather than modelling. A low value is not an error — it says more uploaded data would sharpen it.
NPV / IRR / payback With the discount rate and lifetime you set. The report also states payback in discounted terms.

If you get stuck

“Download the outdoor temperature first” — weather data is missing. Location data sheet → measurement year → fetch. Once per location.
“Enable at least one distribution” — switch on at least one distribution (monthly / weekly / daily) on the demand card.
“T-Curve data not found” — no consumption curve is loaded for this location, or the import was not saved.
“solar split is MODELED” — no inverter export log, so the solar split is estimated. Usable, but the log makes it more accurate.